working volume: 8m³, 12m³, 17m³, 22m³, 28m³
temperature range: -40℃ ~ +100℃
temperature fluctuation: ±0.5℃
temperature uniformity: ≤2.0℃
temperature tolerance: ±2.0℃
heating rate: 3.0℃/min
cooling rate: 2.0℃/min
temperature range for humidity test: +10℃ ~ +85℃
humidity range: 10%RH ~ 98%RH
humidity fluctuation: ±3.0%RH
humidity uniformity: ±5.0%RH
humidity deviation: +2% ~ -3%RH (>75%RH), ±5.0%RH (<75%RH)
power supply: AC380V±10%, 50Hz±1, 3/N/PE, grounding resistance <4Ω
cooling method: Water-cooled
applicable standards: GB/T 2423.1-2008, GB/T 2423.2-2008, GB/T 2423.3-2008, GB/T 2423.4-2008, GB150.3A-2009, GB150.4A-2009, GB150.9A-2009, GB/T 5170.2-2008, GB/T 5170.5-2008
core functions: 32-bit color screen control, Ethernet management, USB data access, APP remote management, over-temperature/smoke/no-wind/power-off ventilation protection, automatic water supply & water shortage alarm, long-term low-temperature operation without defrosting
Internal dimensions (W×D×H):
ETCZ8/4010: 2000×2000×2000mm
ETCZ12/4010: 2000×3000×2000mm
ETCZ17/4010: 2500×3000×2250mm
ETCZ22/4010: 2500×4000×2250mm
ETCZ28/4010: 2500×5000×2250mm
External dimensions (W×D×H):
ETCZ8/4010: 3800×2480×2380mm
ETCZ12/4010: 3800×3480×2380mm
ETCZ17/4010: 4400×3480×2650mm
ETCZ22/4010: 4400×4480×2650mm
ETCZ28/4010: 4400×5480×2650mm