Volume & External Dimensions
1000L: Approx. 1480×2380×2640mm (excluding protruding parts)
1500L: 1250×2560×2300mm (lampshade detachable)
Power Supply & Rating
Power supply: AC380V ±10%, 50Hz ±1, three-phase four-wire + grounding wire (3/N/PE), grounding resistance <4Ω
Max system power: 25.3 KW
Max system current: 43.7 A
Cooling Method: Air cooling
Temperature Parameters (Test per GB/T5170-2008)
Temperature range without radiation: -40℃ ~ +120℃
Temperature range with radiation: -20℃ ~ +100℃
Temperature uniformity: ≤2℃
Temperature fluctuation: ±0.5℃
Temperature deviation: ±2℃
Average heating rate: 3℃/min
Average cooling rate: 1.5℃/min
Native Core Features
Large storage area & high heat load capacity, US PWI refrigerant control technology for low-temperature energy-saving operation, anti-condensation design for test samples, RS232 interface + USB data storage & download function, multi-point alarm monitoring + wireless remote alarm, high-efficiency dehumidification (15 ℃/5% RH)
Universal Standard Functions
Excellent temperature/humidity uniformity & accuracy, Complete safety interlock protection, Low noise operation, Energy-saving design, Automated data logging, High-precision temperature control, Seamless MES integration, Service life: ≥5 years for long-term stable operation
Applicable Standards: GJB150.7-86, GJB150A.7-2009, IEC60068-2-5, GB2423.24, DIN75220, MIL-STD810G