🌍 Envsin Since 2003 ⭐ 23+ Year Industry Experience ✓ Verified Supplier
✓ Verified Supplier
Menu

High and Low Temperature Explosive Decompression Test Chamber

Quantity:
SKU: {{ product.sku }}
Model: {{ product.model }}

{{ variable.name }}

{{ value.name }}
test chamber volume: 1000L working chamber dimensions (W×D×H): 1000×1000×1000mm external dimensions (W×D×H): 1450×3400×2000mm power supply: AC380V±10%, 50Hz±1, three-phase four-wire + ground wire (3/N/PE), grounding resistance < 4Ω max. system power: 52KW max. system current: 80.4A cooling method: Water-cooled (refrigeration unit) temperature range: -70℃ ~ +150℃ temperature uniformity: ≤2.0℃ (no load, normal pressure) temperature deviation: ≤±2.0℃ (no load, normal pressure) temperature fluctuation: ≤±0.5℃ (no load, normal pressure) heating rate: <1℃/min (-55℃ ~ +85℃, full-cycle average, air outlet) cooling rate: <1℃/min (+85℃ ~ -55℃, full-cycle average, air outlet) normal pressure reduction: pressure range: normal pressure ~ 1.0KPa (adjustable); pressure reduction time: ≤30min (normal pressure → 0.5KPa) rapid decompression: decompression range: 75.2KPa ~ 18.8KPa; decompression time < 15s; equipped with vacuum reservoir, stable at 18.8KPa after decompression, overshoot range ±5%; external rapid decompression chamber included (volume < 1/5 of main chamber) explosive decompression: decompression range: 75.2KPa ~ 18.8KPa; decompression time < 0.1s pressure recovery rate: <10KPa/min (adjustable) low pressure temperature performance: temperature deviation < ±5℃; temperature fluctuation ≤±5℃ (4KPa~40KPa), ≤±10℃ (1KPa~4KPa) pressure control accuracy: ±20mbar (≥400mbar); ±5% of target value (20mbar~400mbar); ±1mbar (≤20mbar) test specimen requirement: Suitable for heat-dissipating and non-heat-dissipating samples; heat dissipation power shall not exceed the cooling capacity of the refrigeration system operation remarks: Tested per GB/T 5170-2008 & GB/T 10590-2006; different ambient temperature will affect low temperature performance and cooling capacity core functions: Support combined test of high/low temperature, humidity and pressure, energized test for specimens, Excellent temperature/humidity uniformity & accuracy, Complete safety interlock protection, Low noise operation, Energy-saving design, Automated data logging, High-precision temperature control, Seamless MES integration, Service life: ≥5 years for long-term stable operation applicable standards: GB/T 2423.1, GB/T 2423.2, GB/T 2423.21, GB/T 2423.25, GB/T 2423.26, GJB 360B, GJB 150.2A, GJB 150.3A, GJB 150.4A, GJB 150.6, RTCA/DO-160G