Small High Temperature Aging Chamber
Model & Volume: EWG2003(270L), EWG3003(270L), EWG2010(1000L), EWG3010(1000L)
Temperature range: EWG2003/EWG2010 (R.T+20~200℃); EWG3003/EWG3010 (R.T+20~300℃)
Temperature constancy: ±0.1~±0.8℃
Temperature homogeneity: ±0.5~±2.0℃ (R.T+20~200℃); ±1.5~±3.5℃ (200~300℃)
Temperature deviation: ±0.5~±2.0℃
Heat up time: 50min (R.T→200℃), 90min (R.T→300℃)
Inner dimensions: 600×500×900mm (270L); 850×700×1000mm (1000L)
Outer dimensions: 1000×780×1710mm (270L); 1250×980×1850mm (1000L)
### Large Aging Room
Model & Volume: EWG25(25m³), EWG45(45m³), EWG100(100m³), EWG120(120m³)
Temperature range: R.T+10~85℃
Temperature constancy: ±0.5~±1.0℃
Temperature homogeneity: ±1.5~±3.0℃
Temperature deviation: ±1.5~±3.0℃
Average heating rate: 2℃/min
### Universal Parameters
Power supply: AC380V±10%, 50HZ, 3/N/PE
### Core Functions
Built-in features: Precise temperature control, uniform temperature distribution, over-temperature protection, alarm & fault safety mechanism, energy-saving design, programmable control for test time & temperature
General standard functions: Excellent temperature/humidity uniformity & accuracy, Complete safety interlock protection, Low noise operation, Automated data logging, High-precision temperature control, Seamless MES integration, Service life: ≥5 years for long-term stable operation